• 1800 121 654 321 / 1800 313 158 158
  • info@torqueenergy.in
Subtotal

$ 0.00

Cart is empty

Please add products to your cart.

Wishlist is empty

Please add products to your wishlist.

Compare list is empty

Please add products to compare.

1KVA SMART Wall Mounted Inverter-Inbuilt Lithium Battery

(0)
* Wall Mountable.
* Pollution Free and Safe.
* 5 Years Warranty for Battery, 3 Years Warranty for Inverter.
* 10-15 Years Battery Life.
* Smart Home UPS.
* 3x Faster Charging.
M.R.P.: ₹ 34,800.00
Price: 34,000.00

You Save: ₹ 800.00 (2%)

In Stock

Specification Details

ParameterUnitsRating
Model Name-TLI11280+
Nominal VoltageV12.8
Battery CapacityAh100
Battery PowerWh1280
System Battery Voltage (DC)V12
Charging CutoffV14
Discharging CutoffV11.3
Charging CurrentA @ 0.15C15
Discharging Current RecommendedA @0.8 C80
Charging Temperature°C10°C to 45°C
Discharging Temperature°C0°C to 60°C
Battery WeightKG22 ± 2
Battery Dimensions (LWH)MM442 * 365 * 158
100W Backup @90% DODHr12hr
400W Backup @90% DODHr3hr
Over Charge Protection-Yes
Over Discharge Protection-Yes
Short Circuit Protection-Yes
Charge & Discharge Port-Yes
Audible Noisedb<50
Battery Chemistry
Lithium Ferro Phosphate
Charging Time
5–6 hrs
Backup Time at 400W
>3 hrs
Backup Time at 100W
>10 hrs
INPUT
Power RatingVA1000
DC VoltageV12.8
Voltage RangeVac170–270
FrequencyHc45–65
Full load DC Output CurrentA65
THD%>10% at 220VAC (input)
Input Power FactorLag>0.9
Charger Topology
CONSTANT CURRENT/VOLTAGE
OUTPUT
Power CapacityW800
VoltageVac220 ±7
FrequencyHz50
Power FactorLag0.85
Voltage Harmonic
<5% (Linear Load)
Waveform
Pure Sine Wave
Transient Response
<8% (10%~90% Linear Load)
Low Battery Voltage
Smart Shutdown
Peak Efficiency of Inverter
82%
Crest Factor
3:01
Changeover time (UPS to mains, UPS mode)ms<10
Changeover time (UPS to mains, normal mode)ms<10
Changeover time (mains to UPS mode)ms<10
Changeover time (mains to normal mode)ms<40
Overload capacity (IT 125%)Sec6 sec (6 Auto Retry)
Overload capacity (IT 150%)Sec2 sec (6 Auto Retry)
Overload capacity (Normal 125%)Sec6 sec (6 Auto Retry)
Overload capacity (Normal 150%)Sec2 sec (6 Auto Retry)
Cooling Fan ON temp°C60 or >45% Load
Cooling Fan OFF temp°C55 or >40% Load
DISPLAY
LED Indication
UPS ON
Alarm Function
LED Indication Alarm Function LCD Parameter
LCD Parameter
Battery Voltage, Mains Voltage, UPS ON/OFF, UPS Mode, Load Percentage (0–150%), Overload, Short Circuit, Fault, Battery Low, Over Temperature, Fuse Trip (Customised LCD)


No product review yet. Be the first to review this product.